Starna logo cuvettes main index page reference materials for starna cells home page cuvette, cell and reference material catalogues

Starna® Flow Cells for Spectrophotometers

Download our latest Cell catalogue cuvetter search
Flow Cells
Optical Glass G = Optical Glass 334 - 2500nm
Special optical glass SOG = Special optical Glass 320 - 2500nm
Pyrex PX = Pyrex 325 - 2500nm
UV Silica H = UV Silica 220 - 2500nm
Quartz Q = Far UV Quartz 170 - 2700nm
NI Quartz I = Near infra red Quartz 220 3800nm
Far UV - IR Quartz SX = Far UV - IR Quartz (water free) 170 - 3500nm
Flow cells are used for measuring samples with continuous flow as in chromatography or production systems. They are also used in sipper systems where individual samples are aspirated into the cell. Flow cells are made in a wide array of designs because each application has a different compromise of sample volume, flow pattern, pathlength and tubing requirements. We make a wide range of flow cells and have made every effort to simplify the process of selection as much as possible. If you have questions, please e-mail us and we will answer your technical questions promptly.
Medium Volume, Wide Window, push-on tubing Medium Volume, Wide Window, M6 connectors
Medium Volume Cells, Wide Window, push-on tubing
 Pathlengths: 1, 2, 5, 10, 20, 40, 50  & 100 mm
 materials         Quartz   Far UV - IR Quartz
Standard dimensioned flow cells These cells have quartz tubulations fused to the top for push-on connections with flexible tubing.
Medium Volume Cells, Wide Window, M6 connectors
 Pathlengths: 0.1, 0.2, 0.5, 1, 2, 5,
10, 20, 40, 50  & 100 mm
 materials         Quartz    
Standard dimensioned flow cells These cells have internal threads that use standard M6 connectors
Semi-micro, Medium aperture, Semi-Micro, medium aperture
Semi-micro Cells, Medium aperture,
 Pathlengths: 1, 2, 5 & 10 mm
 materials         Quartz    
Long compartment, screw in connector Fully masked cell with rectangular aperture, optimized for the best flow characteristics for instruments with a long narrow beam geometry
Semi-Micro, medium aperture
 Pathlengths: 5, 10, 20, 40, 50, 100mm
 materials         Quartz    
screw in connectors Fully masked cell with rectangular aperture, optimized for the best flow characteristics for instruments with a narrow beam geometry
Semi-Macro, Wide aperture, Reduced Volume Semi-Micro, Medium aperture
Semi-Macro, Wide aperture, Reduced Volume
 Pathlengths: 1, 2, 5 & 10 mm
 materials         Quartz    
Fully masked cell with square aperture, other optimized for the lowest volume for instruments with a wide or round beam geometry
Semi-Micro, Medium aperture
 Pathlengths: 1, 2, 5, 10, 20, 40, 50  & 100 mm
 materials   Special optical glass     Quartz   Far UV - IR Quartz
Fully masked cell with rectangular aperture, optimized for the best flow characteristics for instruments with a narrow beam geometry
Micro, Short path length, Long aperture Flow Cells, in line or microscope analysis
Micro Cells, Short path length, Long aperture
 materials         Quartz    
 Pathlengths: 0.1, 0.2, 0.5, 1, 2 mm
Fully masked cell with rectangular aperture, optimized for the lowest volume
Flow Cells, in line or microscope analysis
 materials         Quartz    
 Pathlengths: 0.1, 0.2, 0.5, 1 & 2 mm
Flow Cells, in line Flow Cells, Short part length
Flow Cells, in line
 Pathlengths: 0.5, 1, 2, 5, 10 mm
 materials         Far UV Quartz    
Flow Cells, Short part length
 Pathlengths: 0.01, 0.1, 0.2, 1, 2 & 5mm
 materials Optical Glass       Quartz NI Quartz  
Flow Cells, Short part length Demountable Flow Cells, standard and semi-micro
Flow Cells, Short part length Demountable
 Pathlengths: 0.01, 0.1, 0.2, 1, 2 & 5mm
 materials Optical Glass       Quartz    
Flow Cells, standard and semi-micro
 Pathlengths: 10 mm
 materials   Special optical glass     Quartz    
Sub micro round aperture Micro, sub micro round aperture
Sub micro Cells round aperture
 Pathlengths: 1, 2, 5, 10, 20 & 50mm
 materials   Special optical glass     Quartz   Far UV - IR Quartz
Micro, sub micro round aperture
 Pathlengths: 10 mm
 materials         Quartz    
Vacuum / debubbler
Micro with round aperture round aperture
Micro Cells with round aperture
 Pathlengths: 2, 5, 10, 20 & 40mm
 materials   Special optical glass     Quartz   Far UV - IR Quartz
round aperture cells
 Pathlengths: 1, 2, 5, 10, 20, 40, 50  & 100 mm
 materials   Special optical glass     Quartz   Far UV - IR Quartz
Dissolution micro aperture Semi-Micro, Short path length Long aperture
Dissolution Cells micro aperture
 Pathlengths: 10 mm
 materials         Quartz    
Semi-Micro, Short path length Long aperture
 Pathlengths: 0.01, 0.05, 0.1 0.2, 0.5, 1& 5 mm
 materials         Quartz    
Ultra-micro & sub micro round aperture round aperture
Ultra-micro & sub micro Cells, round aperture
 Pathlengths: 10 mm
 materials   Special optical glass     Quartz   Far UV - IR Quartz
round aperture Cells
 Pathlengths: 10, 20, 40, 50 & 100 mm
 materials   Special optical glass     Quartz    
HPLC round aperture76/ss Micro aspiration
HPLC Cells round aperture76/ss
 Pathlengths: 10 mm
 materials   Special optical glass     Quartz    
Micro aspiration Cells
 Pathlengths: 10 mm
 materials         Quartz    

Starna main nav bar starna home page cuvettes main index reference materials starna contacts faq.s optical coatings prisms optical mirrors
Cells Reference materials Mirrors Prisms lenses coatings
Email:sales@starna.co.uk
©Starna.co.uk all rights reserved 2000-04